R&D

Taeyoung is dedicated to providing superior product and innovation
  • Classification Name Use Range Explanation Note
    Classification

    Analysis Test

    Name

    GC/MS
    (Gas chromatography-Mass Spectrometry)

    Use

    VOCs Precision Analysis

    Range

    1~1,200amu

    Explanation

    Analyze Benzene, Toluene, Ethylbenzene, Xylene, Styrene

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Analysis Test

    Name

    FT-IR
    (Fourier-transform infrared spectroscopy)

    Use

    High Polymer Analysis

    Range

    4,000~450cm-1

    Explanation

    Analyze hi-polymer structure(Base material and adhesive)

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Analysis Test

    Name

    HPLC
    (High-Performance Liquid Chromatography)

    Use

    Aldehydes Precision Analysis

    Range

    190~706nm

    Explanation

    Analyze Formaldehyde, Acetaldehyde, Acrolein

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Analysis Test

    Name

    XRF
    (X-ray Fluorescence)

    Use

    Heavy Metal Analysis

    Range

    13 Aluminium
    ~ 92 Uranium

    Explanation

    Analyze Cadmium, Bromine(6+), Lead, Mercury

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Measurement Test

    Name

    Abrasion Tester
    (needle type)

    Use

    Durability Test

    Range

    0 ~ 60 Cycle

    Explanation

    Test Durability of Abrasion

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Temperature Test

    Name

    Constant-Temperature Oven

    Use

    Heat-Resistance Test

    Range

    Max. 250℃

    Explanation

    Test durability and reliability in high and low temperature

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Temperature Test

    Name

    Thermo-Hygrostat Chamber

    Use

    Cold and Moisture Resistance Test

    Range

    temperature: -40~150℃
    Humidity: 25~98%

    Explanation

    Test durability and reliability in cold temperature and humid condition

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Temperature Test

    Name

    Heat Reflection Performance Tester

    Use

    Heat Reflection Performance Test

    Range

    Max. 1,000℃

    Explanation

    Evaluate protectability of interior material in high temperature

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Flame Retardant Test

    Name

    Combustibility Tester
    (horizontal type)

    Use

    Combustibility Test

    Range

    400×200×307mm

    Explanation

    Evaluate combustibility of single and assembled object

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Flame Retardant Test

    Name

    Flame Retardant Tester

    Use

    Flame Retardant Test

    Range

    360×460×610mm

    Explanation

    Evaluate combustibility of assembled object

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Electrical Test

    Name

    Withstand Voltage Tester

    Use

    Withstand Voltage Test

    Range

    0~10kV

    Explanation

    Evaluate electrical characteristic in conductive condition

    Note

  • Classification Name Use Range Explanation Note
    Classification

    Noise Test

    Name

    Noise Level Tester

    Use

    Noise Level Test

    Range

    20~140dB

    Explanation

    Evaluate changing of impact noise

    Note